Product Details:
Minimum Order Quantity | 100 Piece |
Brand | CHINA |
Usage/Application | RELAY MODULE |
Coil Voltage | Maximum Current 10A @250VAC, 10A @125VAC |
1 Channel 5V Relay module is used as a switching device and as it is a single channel this module can control only a single circuit. Relay modules with multiple channels can control multiple circuits.
This module consists of 6 input-output pins i.e., Vcc, GND, IN, Common (COM), Normally Closed (NC) and Normally Open (NO). Vcc and GND are the two ends of the coil inside the relay. These pins are used to trigger ON/OFF the relay. Vcc is connected to 5V DC and GND is connected to the ground. At Input pin, we give a signal from a microcontroller to allow/disallow current to flow through the coil. Common is connected to one end of the device to be controlled. The other end of the load is either connected to the NC or NO. If the load is connected to NC then the device remains connected before trigger and if it is connected to NO then the device remains disconnected before trigger. The trigger voltage of this module is 5 V.
Devices operating on 10A, 250V AC and 10A 30V DC can be used as load devices for this module. When the trigger voltage is supplied the coil is turned ON and then the contact between common to NC is changed to common to NO. and when trigger voltage is not supplied to the relay the contact comes back to common to NC from common to NO.
1 Channel 5V Relay module is used as a switching device and as it is a single channel this module can control only a single circuit. Relay modules with multiple channels can control multiple circuits.
This module consists of 6 input-output pins i.e., Vcc, GND, IN, Common (COM), Normally Closed (NC) and Normally Open (NO). Vcc and GND are the two ends of the coil inside the relay. These pins are used to trigger ON/OFF the relay. Vcc is connected to 5V DC and GND is connected to the ground. At Input pin, we give a signal from a microcontroller to allow/disallow current to flow through the coil. Common is connected to one end of the device to be controlled. The other end of the load is either connected to the NC or NO. If the load is connected to NC then the device remains connected before trigger and if it is connected to NO then the device remains disconnected before trigger. The trigger voltage of this module is 5 V.
Devices operating on 10A, 250V AC and 10A 30V DC can be used as load devices for this module. When the trigger voltage is supplied the coil is turned ON and then the contact between common to NC is changed to common to NO. and when trigger voltage is not supplied to the relay the contact comes back to common to NC from common to NO.
Operating Voltage | 5V DC |
Maximum Current | 20 mA |
Maximum Current | 10A @250VAC, 10A @125VAC |
Dimensions(LxBxH) | 44x77x20 (mm) |
Additional Information:
Product Details:
Minimum Order Quantity | 100 Piece |
Mounting Type | DIP |
This is an 8 Channel 5V 10A Relay Module with optocoupler. The output rating for each relay is 230 volts 10 Ampere or 10 ampere at 30 volt DC. Since each relay is provided with independent common terminal along with Normally Open (NO) and Normally Closed (NC) pins it is very easy to use. Each trigger pin is isolated from the relay using a opto-coupler thus making sure your circuit is saved.. 8 LED indicators are provided to display the individual Relay Status. The relays can be controlled directly by a wide range of microcontrollers such as Arduino , 8051, AVR, PIC, PLC,DSP, ARM, ARM, MSP430, TTL logic circuits, etc.
This is an 8 Channel 5V 10A Relay Module with optocoupler. The output rating for each relay is 230 volts 10 Ampere or 10 ampere at 30 volt DC. Since each relay is provided with independent common terminal along with Normally Open (NO) and Normally Closed (NC) pins it is very easy to use. Each trigger pin is isolated from the relay using a opto-coupler thus making sure your circuit is saved.. 8 LED indicators are provided to display the individual Relay Status. The relays can be controlled directly by a wide range of microcontrollers such as Arduino , 8051, AVR, PIC, PLC,DSP, ARM, ARM, MSP430, TTL logic circuits, etc.
Channels | 8 |
Operating Voltage | 5V |
Max Switching Current (AC) | 10A @250V AC |
Max Switching Current (DC) | 10A @30V DC |
Dimension (LxW) | 140x58 mm |
Additional Information:
Product Details:
Minimum Order Quantity | 500 Piece |
Brand | UNIQUE INDIA SALES |
It is 4 Channel Isolated 5V 10A Relay Module, A wide range of microcontrollers such as Arduino, AVR, PIC, ARM and so on can control it.
It is also able to control various appliances and other types of equipment with large current.
Relay output maximum contact is AC250V 10A and DC5V 10A. One can connect a microcontroller with standard interface directly to it.
Red working status indicator lights are conducive to the safe use. It has a wide range of applications such as all MCU control, industrial sector, PLC control, smart home control.
Ready to get switching on your Raspberry Pi?! This neat relay module features 4 x 5V relays rated at 10A/250V each. It is designed to switch up to 4 high current (10A) or high voltage (250V) loads with the help of microcontroller!
Additional Information:
Product Details:
Voltage | Trigger Voltage (Voltage across coil) 24V DC |
Current | Maximum DC load current 10A @ 30/28V DC |
Usage/Application | home automation, switching circuits, security circuits, etc. |
Number Of Poles | SINGLE |
Mounting Type | DIP |
SPDT(Single Pole Double Throw) relay is used as a switch for high current AC/DC appliances which need to be controlled from a microcontroller or sensor output. 24V PCB Mount Sugar Cube SPDT Relay instead of its small size can switch a load of 7A connected to it. The coil resistance of this relay is 1.6k ohm whereas the coil current is 15 mA. The trigger voltage for this relay is 24V.
There are 5 pins in this relay i.e, Coil end 1, Coil end 2, COM(common), NC and NO. Coil end 1 and Coil end 2 are used to trigger ON/OFF the relay. One end is connected to a 24V supply and the other is connected to the ground of the circuit. Common is connected to the one end of the load to be controlled. The other end of the load is connected to either NC or NO. If the load is connected to NC(Normally Closed) then the load remains ON before trigger. And if it is connected to NO(Normally Open) then the load remains OFF before trigger. These relays are usually used in home automation, switching circuits, security circuits, etc.